Vicks SpeedRead Digital Thermometer Parts
- Probe Tip
- On/Off Button
- Large Display with Fever InSight backlight
- Battery Compartment (on the back side)
What to Buy with Vicks SpeedRead Thermometer
How to use Vicks Speedread Digital Thermometer?
1. TURNING THE UNIT ON
- Turn the unit on by pressing the On/Off button
- A beep will sound, and the display will flash Red/Yellow/Green for 1 second
- Wait for the unit to get ready
– The display will perform a self-test
– The display will show the last measurement for 2 seconds
– After about 5 seconds, the display will show it’s ready
2. SELECTING A TEMPERATURE LOCATION
Oral Use
- It is suggested to use a probe cover for Oral Use to prevent the spread of germs
- Place the thermometer under the tongue. It is important to place the tip of the thermometer well under the tongue to get a good, accurate reading. (Fig. 5) Place the sensor tip in areas marked with “3”. Keep mouth closed and sit still to help ensure an accurate measurement
- When the peak temperature is reached (usually 9 seconds), 5 beep signals will sound, and the “°F” or “°C” sign will stop flashing. The temperature is now ready to read and will not change when the thermometer is removed
- Dispose of the used probe cover and wash the thermometer as recommended
Under-the-arm (Axillary) Use
This method is used for babies and young children
- Wipe the underarm with a towel
- Place the probe tip under the arm so the tip is touching the skin, and position your arm next to your body. With a young child, it is sometimes helpful to hug the child to keep their arm next to their body. This ensures that the room air does not affect the reading
- When the peak temperature is reached (usually 11 seconds), 5 beep signals will sound, and the “°F” or “°C” sign will stop flashing. The temperature is now ready to read and will not change when the thermometer is removed
- Wash the thermometer as recommended
Note: This method produces a temperature 1° lower than a temperature taken orally
Rectal Use
- Commonly used for babies, young children, or when it is difficult to take an oral or underarm temperature
- Cover the thermometer’s tip with a probe cover and lubricate with a water-soluble jelly for easier insertion. Do not use petroleum jelly. Read the label of the lubricant to be sure you are using the right kind
- Lay the patient on his/her side. If the patient is an infant, the proper position for a baby is to lay on its stomach with legs hanging down, either across your knees or at the edge of a bed or changing table. This positions the infant’s rectum for safe and easy insertion of the thermometer
- Gently insert the tip of the thermometer NO MORE THAN 1/2 inch into the rectum. If you detect resistance, stop. Hold the thermometer in place during the measurement
- When the peak temperature is reached (usually 10 seconds), 5 beep signals will sound, and the “°F” or “°C” sign will stop flashing. The temperature is now ready to read and will not change when the thermometer is removed
- Dispose of the used probe cover and wash the thermometer as recommended
Note: This method produces a temperature 1° higher than a temperature taken orally
Cleaning Instructions
- Clean the probe tip by washing it with soap and warm water or by disinfecting it with rubbing alcohol (70% isopropyl alcohol)
- Wipe dry with a soft cloth
- DO NOT BOIL OR CLEAN IN DISHWASHER
- Do not wash the unit with any thinner or chemical solvent
Precautions
- High, prolonged fever requires medical attention, especially for young children
- Do not allow children to take their temperatures unattended
- Do not allow children to walk or run during temperature-taking
Speedread Digital Thermometer Fever Insight Specifications
Particulars |
Specifications |
Battery Life |
More than 300 measurements or approximately 2 years if used every other day |
Temperature Range |
89.6-109.2°F. If less than 89.6°F, “Lo” is displayed. If more than 109.2°F, “Hi” is displayed. |
“BPA Free” Implies |
- Plastics used to make the thermometer are BPA Free
- A comprehensive audit to ensure a BPA Free process
- A screening test based on acceptance criteria
|
Beeper |
Unit will beep for approximately 8 seconds when peak temperature is reached. For temperatures over 101.0°F, the audible Fever Signal will sound 5 times. |
Error Messages |
The display will read “Err” when a malfunction occurs and the unit will power off after 1 minute. |
Accuracy in Water-bath |
+/-0.2°F between 96.0-107.0°F at room temperature of 71°F. |
Vicks SpeedRead Digital Thermometer Warranty
1 Year Limited Warranty.
Related Articles
{{x.ShortDescription}} ...
Share