Save 25% On Your First Autoship Order

Day
:
:
Online since 2002 |   +1 866-316-0162

View product option

Monaghan AeroChamber Mini Aerosol Holding Chamber

Product Option

Capacity: 110cc

SKU 98810
$38.20 Each

Capacity: 110cc

SKU 98810
$381.47 10/Pack
Request quote

Monaghan AeroChamber Mini Aerosol Holding Chamber is a new and unique device, designed to deliver pMDI aerosols to patients in conjunction with mechanical ventilation, manual resuscitation bag and standard aerosol resuscitation mask. It is comprised of an anti-static, dual chamber design. The patented exhalation channel has one way valve that preserves aerosol dose and minimizes dead space.

Mini Aerosol Holding Chamber Highlights

  • Single patient use
  • FSA Approved
  • Hygiene Product
  • Easy-to-use

Autoship

$28.65 $50.85

25% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $1.91 in HPFY rewards

One-time purchase

$38.20 $50.85

Earn $1.91 in HPFY rewards

AeroChamber Mini Aerosol Holding Chamber Features

  • 110cc ergonomically correct chamber that fits comfortably in hand
  • AeroDock canister port makes this mini chamber a device designed to accept standard pMDIs as well as those with integrated dose counters
  • Can be easily connected to the endotracheal tube in front of a wye or HME in a ventilator circuit
  • In a ventilator circuit it is designed to maintain positive end expiratory pressure
  • Also can be used with a standard aerosol resuscitation mask and is effective for use with low tidal volume patients
  • Comprised of the StatBan anti-static, dual chamber design
  • Innovative exhalation channel minimizes dead space for the low tidal volume patient and maintains optimum aerosol dose
  • Single patient use


Parts Description:

Monaghan AeroChamber Mini Aerosol Holding Chamber


Frequently Bought Together

How to use Mini Aerosol Holding Chamber?

Instructions For Use With Resuscitation Bag:

  • If using a GlaxoSmithKline MDI canister equipped with an integrated dose counter, remove the Canister Adapter from the unit. For all other canisters leave white Canister Adapter in port.
  • Attach the resuscitation bag to the AeroChamber mini HC.
  • Shake the MDI canister immediately before use as per the instructions supplied with the MDI.
  • Insert the MDI canister into the Canister Port of the AeroChamber mini HC.
  • Dsconnect the patients endotracheal or tracheal tube from the ventilator circuit. Immediately attach the Monaghan AeroChamber mini HC to the endotracheal or tracheal tube and re-establish ventilatory support. The arrow on the device should always point towards the patient and the Canister Port must be on top as shown.
  • While holding the MDI canister vertically, depress the MDI. Immediately deliver a manual breath by squeezing the resuscitation bag. Administer one puff at a time to achieve the prescribed number of doses.
  • Following treatment, disconnect the AeroChamber mini HC from patient and reconnect ventilator circuit to patients endotracheal or tracheal tube. Return the AeroChamber mini HC to its protective bag.

Instructions For Use In Ventilator Circuit:

  • Remove the Canister Adapter from the device if you're using a GlaxoSmithKline MDI canister that has a built-in dose counter. Leave the white Canister Adapter in the port for all other canisters.
  • As per the directions included with the MDI, shake the MDI canister right before use.
  • Place the MDI canister into the AeroChamber tiny HC's Canister Port.
  • Disconnect the patient's endotracheal airway's connection to the ventilator circuit. Re-establish ventilatory assistance right away by fastening the AeroChamber small HC's one end to the patient's endotracheal tube and the other end to the wye vent circuit. The Canister Port must be on top as illustrated and the arrow on the device must always point in the direction of the patient
  • Before starting inspiration, fully depress the MDI while holding the canister of the MDI vertically. To administer the recommended number of dosages, take one puff at a time.
  • Wait before performing step 5 again as directed. Make that the patient is properly ventilated in between administering the required puffs. After treatment, remove the patient's AeroChamber small HC and re-connect the ventilator circuit to the patient's trachea or endotracheal tube. Put the AeroChamber small HC back in its sleeve.

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close