Save 25% On Your First Autoship Order

Day
:
:
Online since 2002 |   +1 866-316-0162

View product option

Milliken ULTRA Silver Foam Dressing

Product Option

4 inches x 5 inches

SKU 3000051018
$12.51 Each

4 inches x 5 inches

SKU 3000051018
$269.04 10/Pack
$26.9 Each
Request quote

Milliken ULTRA Silver Foam Dressing transfers moisture away from the wound and across the foam, utilizing more foam capacity while protecting the peri-wound. It kills a wide range of pathogens commonly associated with wounds. Combines the moisture management benefits of AFM Technologys three-part design with a proprietary ceramic silver ion technology.

Autoship

$9.38 $17.89

25% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $0.63 in HPFY rewards

One-time purchase

$12.51 $17.89

Earn $0.63 in HPFY rewards

ULTRA Silver Foam Dressing Features

  • Stays intact when exposed to exudate and upon removal
  • Inactivates pathogens to reduce the risk of infection
  • Can be cut to size without unraveling
  • Minimizes risk of maceration
  • Protects healthy intact skin
  • Indicated for the management of acute and chronic wounds: partial-thickness burns, incisions, skin grafts, donor sites, lacerations, abrasions, and Stage I-IV dermal ulcers (vascular, venous, pressure, and diabetic)
  • Antimicrobial activity is demonstrated for up to three days

ULTRA Silver Foam Dressing User Manual
ULTRA Silver Foam Dressing Instruction Guide

Directions for Use:

  • ULTRA Silver dressings can be used throughout the healing process
  • Prepare the wound bed according to the clinical protocol such as debridement and/or cleaning and rinsing with sterile saline or water
  • Remove the dressing from the package and apply it to the wound with the printed side of the dressing away from the wound
  • The optimal performance of ULTRA Silver dressings requires direct contact with the wound
  • ULTRA Silver dressings should not be folded. If required, ULTRA Silver dressings can be cut to various shapes and sizes
  • ULTRA Silver dressings can be secured with an appropriate dressing such as roll gauze, adhesive border gauze, composite island dressing, transparent film, or tape

Directions for Removal:

  • ULTRA Silver dressings should be changed when clinically indicated or as prescribed by a healthcare professional
  • Carefully remove the fixative and the dressing from the wound
  • Normally the dressing does not adhere to the wound. If adherence is observed, the dressing can be moistened with sterile saline or water to ease removal

Contraindications of ULTRA Silver Foam Dressing

  • Should not be used on patients with a known sensitivity to silver
  • In case of an allergic reaction, discontinue use immediately and contact your healthcare provider

Precautions for Silver Foam Dressing

  • ULTRA Silver dressings are not approved for use directly on full-thickness burns
  • The Active Fluid Management performance of ULTRA Silver dressings may be impaired by use with petrolatum-based ointments

More Information

  • Contraindications:
    - 
    Should not be used on patients with a known sensitivity to silver
    - In case of allergic reaction, discontinue use immediately and contact your healthcare provider
  • Dressing Architecture:
    Protection Layer:

    - The layer that makes contact with the wound bed and surrounding healthy skin
    - Supports 2 critical functions: regulating moisture and protecting healthy skin
    - Unidirectional fibers only wick moisture vertically through this layer
    Micro-Knit Process:
    - Proprietary technology created by Milliken Healthcare Products, LLC
    - Creates the transferring mechanism by which the two layers interact
    - Facilitates balance and regulates moisture at the wound bed
    Transfer Layer:
    - Designed to be extremely hydrophilic
    - Pulls exudate through the Protection Layer, distributes and transfers it intosecondary dressing
    - Creates a continuous capacity to handle moisture and exudate
  • Directions for Use:
    - ULTRA Silver dressings can be used throughout the healing process
    - Prepare the wound bed according to the clinical protocol such as debridement and/or cleaning and rinsing with sterile saline or water
    - Remove the dressing from the package and apply to the wound with the printed side of the dressing away from the wound
    - Optimal performance of ULTRA Silver dressings requires direct contact with the wound
    - ULTRA Silver dressings should not be folded. If required, ULTRA Silver dressings can be cut to various shapes and sizes
    - ULTRA Silver dressings can be secured with an appropriate dressing such as roll gauze, adhesive border gauze, composite island dressing, transparent film or tape.
  • Directions for Removal:
    - ULTRA Silver dressings should be changed when clinically indicated or as prescribed by a healthcare professional
    - Carefully remove the fixative and the dressing from the wound
    - Normally the dressing does not adhere to the wound. If adherence is observed, the dressing can be moistened with sterile saline or water to ease removal
  • Precautions:
    - ULTRA Silver dressings are not approved for use directly on full thickness burns
    - The Active Fluid Management performance of ULTRA Silver dressings may be impaired by use with petrolatum-based ointments.
  • Storage: ULTRA Silver dressings should be stored at temperatures less than 131 °F. Keep dry

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close