Why choose Drive Nebulizer Machine?
What to buy with Compressor Nebulizer for Breathing Treatment?
Also Available (Separately):
How to use Drive Airial MEDNEB Plus Compressor Nebulizer?
- Operating the Compressor:
1. Before each use inspect the Compressor and nebulizer cup assembly for damage or wear, and replace as needed.
2. Place the Compressor on a table or other flat stable surface. Be sure to easily reach the controls when seated. Do not use this device on the floor.
3. With the power switch in the O (OFF) position, plug the power cord into an appropriate electrical wall outlet.
4. Connect one end of the tubing to the compressor air-outlet connector.
5. Assemble the Airial nebulizer cup and add indicated medication to the nebulizer cup before use.
6. Attach the other end of the tubing to the air-inlet connector found at the bottom of the nebulizer cup.
7. Turn on the Compressor by pressing the power switch to the I (ON) position and begin treatment.
8. If treatment needs to be interrupted, simply press the power switch to the O (OFF) position.
9. When the treatment is complete, turn off the compressor by pressing the power switch to the O (OFF) position and unplug the unit from the electrical outlet.
10. Always unplug this Airial nebulizer immediately after use.
11. Do not use this product in or near explosive environments, or where aerosol (spray) products are being used.
12. Do not pump combustible liquids or vapors with the product or use in or near an area where flammable or explosive liquids or vapors may exist.
13. Do not operate this product in an oxygen-enriched environment, i.e. oxygen tent or oxygen hood.
14. Use only in well-ventilated areas.
- How to Take the Treatment?
- Sit up straight and breathe in deep
- Breathe in so deeply that it feels as though the lungs are completely full of air and inhaling any additional air is impossible
- If possible, hold the breath for 1-2 seconds unless directed otherwise by the physician and then slowly exhale through the nebulizer mouthpiece or mask
- Holding the breath for 1-2 seconds after inhaling the medication allows for optimal absorption of medication in the lungs
- Repeat this breathing pattern for the entire treatment
- Nebulizer Cleaning:
1. With the power switch in the Off position, unplug the power cord from the wall outlet.
2. Disconnect the tubing from the air-inlet connector and set aside.
3. Disassemble the mouthpiece or mask from the cap. Open the Aerial nebulizer by turning the cap counterclockwise and removing the baffle.
4. Wash all items, except tubing, in a hot water/dishwashing detergent solution. Rinse under hot tap water for 30 seconds to remove detergent residue. Allow to air dry.
5. Drive Reusable Nebulizer is dishwasher safe, but do not place any Drive Disposable Nebulizer parts in an automatic dishwasher; doing so could cause damage
- Compressor Cleaning:
1. With the power switch in the Off position, unplug the power cord from the wall outlet.
2. Wipe the outside of the compressor cabinet with a clean damp cloth every few days to keep it dust-free.
3. Do not submerge in water; doing so will result in compressor damage.
Medneb Compressor Nebulizer Machine Specifications
Particulars |
Specifications |
Power |
AC 120V, 60Hz |
Current |
Max. 1.5A |
Medication Capacity |
5ml |
Particle Size |
0.5 to 10 um |
MMAD |
4 um |
Sound Level |
60 dBA |
Maximum Medication capacity |
13 ml (cc) |
Average Nebulization Rate |
= 0.18ml/min |
Compressor Pressure Range |
17.4 to 29 Psi (0.12 to 0.2 Mpa) |
Operating Pressure Range |
7.25 to 10 Psi (0.05 to 10.07 Mpa) |
Liter Flow Range |
5 ~ 8 lpm |
Operating Temperature Range |
10°F) |
Storage Humidity Range |
10% to 95% RH |
Dimension (L x W x H) |
170 mm x 136 mm x 90 mm |
Drive Airial Nebulizer Warranty
5 year limited warranty, Your Drive brand product is warranted to be free of defects in materials and workmanship for ve years of the original consumer purchaser. This device was built to exacting standards and carefully inspected prior to shipment. This five year limited warranty is an expression of our confidence in the materials and workmanship of our products and our assurance to the consumer of years of dependable service. This warranty does not cover device failure due to owner misuse or negligence, or normal wear and tear. The warranty does not extend to non-durable components, such as filters, rubber accessories, and rubber grips, which are subject to normal wear and need periodic replacement. If you have a question about your Drive device or this warranty, please contact an authorized Drive Dealer.