Features of Drive Med-Aire Bariatric Alternating Pressure Mattress
- 3 diagnostic audio and visual alarms alert for issues with air pressure, the system, or power
- The system includes 20 individual air cells to maximize immersion and envelopment with a pillow feature for head stability & comfort
- Advanced Clinical and Care Giver Features: Auto-Firm, Seat Inflate, auto-recovery, microprocessing feedback, lock-out, and more!
- Cell-on-cell designed air cells prevent "bottoming out" and provide up to 24 hours of power outage protection
- 10" deep air cells are easily removed with quick disconnects for convenient servicing
- The removable quilted Nylon cover is fluid-resistant, low-shear, and vapor permeable, helping protect the skin from friction and moisture
- CPR valve allows for rapid deflation
- Tubing quickly and easily disconnects with EZ Lock/Quick Release design
- Active combination bariatric therapy system provides both alternating pressure and low air loss to optimize pressure redistribution, shear/friction reduction, and microclimate control
- Designed to prevent, treat and heal all stages of pressure ulcers in the home or long-term care setting
- The digital control unit offers 4 cycle times and adjustable comfort weight settings for optimal immersion and patient satisfaction
Drive Med-Aire Alternating Pressure Mattress User Manual
What to buy with Alternating Pressure Mattresses
How to position the patient on Drive Bariatric Alternating Pressure Mattress?
A suitable way to verify that the patient is not bottoming out is to perform a hand check as described below:
- Ensure that the patient is lying supine (on his/her back) in the middle of the mattress.
- Place a hand with four (4) fingers stacked vertically beneath the air cell directly underneath the sacral region.
- Ensure that the 4 fingers can slide with minimal resistance between the patient’s sacral region and the lower portion of the mattress.
- Adjust the comfort setting as needed.
- Wait for the mattress to adjust to the selected range.
- Revaluate with the hand check and adjust to patients’ comfort level.
How to clean and maintain Drive Med-Aire Mattress?
- Remove any soiled or used bedding.
- Examine the mattress for visible spoilage of bodily fluids.
- If no disinfection is required, brush off or wipe down all surfaces of the cover sheet with soap and water before wetting with any liquid disinfectant.
- If disinfection is required, follow the procedure below:
- Use rubber gloves and eye protection.
- Unzip the top cover from the mattress.
- Prepare detergent/disinfectant solution (registered by the EPA recommended) according to the preparation recommended for correct use-dilution.
- 1:9 Bleach and water dilution may be used.
- With the mattress fully deflated, wipe down all surfaces around and in between the air cells, including the cells.
- Covers may be immersed and soaked in disinfectant for the required incubation period. After pre-soaking, the cover may be rinsed through a regular cycle in a washer with no soap and then laundered with mild detergent (wash temperature 93°F/34°C, rinse temperature 78°F/26°C or on the coldest setting).
- Allow all covers and parts to aerate until they are fully dry
- Repeat the process with the tubing set: spray/wipe, incubate, and air dry.
- Dry the mattress on a flat surface area after cleaning, away from exposure to the sun.
- Avoid long exposure to sunlight.
Warning:
To reduce the risk of burns, electrocution, fire, or injury to persons:
- A product should never be left unattended when plugged in
- Close supervision is necessary when this product is used by, on, or near children or invalids
- Use this product only for its intended use as described in this manual
- Do not use attachments not recommended by the manufacturer
- Never operate this product if it has a damaged cord or plug if it is not working properly, if it has been dropped or damaged, or dropped into water.
- Return the product to a service center for examination and repair
- Keep the cord away from heated surfaces
- Never block the product's air openings or place them on a soft surface, such as a bed or couch, where the air openings may be blocked.
- Keep the air openings free of lint, hair, and the like
- Never drop or insert any object into any opening or hose
- Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered
- Connect this product to a properly grounded outlet only.
Med-Aire Plus Alternating Pressure Pump and Mattress Specifications
Particulars
|
Pump
|
Power
|
120 VAC
|
Input Frequency
|
60 Hz
|
Pressure Range
|
20mmHg to 60mmHg (inner mattress pressure)
|
Auto Firm |
60mmHg, auto return in 30 minutes |
Se at Function |
Pressure preset + 10mmHg |
Function Lock |
Auto lock in 30 minutes after On |
Air Flow
|
12LPM (Litres Per Minute)
|
Functions
|
Static and dynamic features
|
Power Cord Length
|
15ft
|
Pump Dimensions
|
14.5"L x 5"W x 10"H
|
Maximum Current
|
0.5amps
|
Particulars
|
Mattress
|
Base Material
|
Zippered Vinyl
|
Dimensions
|
54"W x 80"L x 10"H
|
Maximum Support Capacity
|
1000lb
|
Drive Med-Aire Plus Bariatric Mattress Warranty
18 months warranty for control unit and mattress