Drive Fingertip Pulse Oximeter Features
- Operation of the product is simple and convenient
- Drive Fingertip Pulse Oximeter is small in volume, light in weight (total weight is about 50g, including batteries), and convenient to carry
- Power consumption of the product is low, and the two originally equipped AAA batteries can be operated continuously for 20 hours
- The product will automatically be powered off when no signal is in the product within 5 seconds
When to use Drive Pulse Oximeters?
Pulse oximeters are used regularly in all conditions that tend to affect blood oxygen saturation levels:
What are normal SpO2 levels?
When a person's activity level changes during the day, the values of the pulse oximeters, or oxygen saturation (the amount of oxygen transported by the blood in relation to its maximal capacity), may change. You must check your blood oxygen level four to five times per day and record the results with the things you did just before the check to calculate your average value.
- Most people consider a SpO2 of > or = 95% normal.
- Hypoxemia is indicated by a SpO2 of or = 92 percent (at sea level).
If the SpO2 falls below 92 percent, patients with acute respiratory illnesses like influenza or an asthma attack may require oxygen supplementation.Â
What to buy with Drive MQ3000 Fingertip Pulse Oximeter
What is the principle of the Drive Oximeter?
An experience formula of data process is established by taking use of Lambert Beer Law according to Spectrum Absorption Characteristics of Reductive Hemoglobin (11b) and Oxyhemoglobin (HbO,) in glow & near-infrared zones. The operation principle of the instrument is: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology so that two beams of different wavelengths of light can be focused onto a human nail tip through perspective clamp finger-type sensor. Then measured signal can be obtained by a photosensitive element, information acquired through which will be shown on screen through treatment in electronic circuits and microprocessors.
How to use Drive Fingertip Pulse Oximeter with LED Display?
How to install Drive Pulse Oximeter?
Battery
- Refer to Figure 3. and insert the two AAA-size batteries properly in the right direction.
- Replace the cover.
- Note: Please take care when you insert the batteries for the improper insertion may damage the device.
Mounting the lanyard
- Put the end of the lanyard through the hole.
- Put another end of the lanyard through the first one and then tighten it.
Â
How to operate Drive Oxygen Monitor?
- Insert the two batteries properly to the direction, and then replace the cover.
- Open the clip as shown in Figure 5.
- Let the user’s finger put into the rubber cushions of the clip (make sure the finger is in the right position), and then clip the finger.
- Press the switch button once on the front panel.
- Do not shake the finger and keep the user at ease during the process. Meanwhile, the human body is not recommended in movement status.
- Get the information directly from the screen display.
Â
How to maintain Drive LED Fingertip Pulse Oximeter?
- Please change the batteries when the low-voltage is displayed on the screen.
- Please clean the surface of the device before using it. Wipe the device with medical alcohol first, and then let it dry in the air or clean it with a dry clean fabric.
- Using the medical alcohol to disinfect the product after use to prevent cross infection for next use.
- Please take out the batteries if the oximeter is not used for a long time.
- The best storage environment for the device is - 40°C to 60°C ambient temperature and not higher than 95% relative humidity.
Drive Fingertip Pulse Oximeter with LED Display User Manual
Warnings:
- Explosive hazard-DO NOT use the oximeter in an environment with flammable gas such as ignitable anesthetic agents.
- DO NOT use the oximeter while MRI and CT measure the user.
- The disposal of scrap instruments and their accessories and packing (including batteries, plastic bags, foams, and paper boxes) should follow local laws and regulations.
- Please check the packing before use to ensure the device and accessories are in accordance with the packing list, or else the device may work abnormally.
- Please don’t measure this device with function test paper for the device’s related information.
Caution:
- This product contains natural rubber latex, which may cause allergic reactions.
- The finger should be placed properly (see the attached illustration of this manual ,Figure 5), or else it may cause inaccurate measurement.
- The SpO2 The sensor and the photoelectric receiving tube should be arranged with the subject’s arteriole in a position there between.
- The SpO2 The sensor should not be used at a location or limb tied with arterial canal or blood pressure cuff or receive- ing intravenous injection.
- Make sure the optical path is free from optical obstacles like rubberized fabric.
- Excessive ambient light may affect the measuring result. It includes a fluorescent lamp, dual ruby light, infrared heater, direct sunlight, etc.
- Strenuous action of the subject or extreme electrosurgical interference may also affect the accuracy.
- User can not use enamel or other makeup.
Fingertip Pulse Oximeter by Drive Specifications
Applications |
Specifications |
Battery Duration |
20 to 30 hours |
Dimensions |
2.2(L) x 1.2(W) x 1.3(H) |
Manufacturer Warranty |
2 Years Warranty |
Weight |
1.8 oz |
Warranty