Features of Drive Balanced Aire Powered Convertible Mattress
- 2.5" Hybrid Visco Foam Top Layer:
- Provides immersion, premium comfort, and heat dissipation
- High-density foam perimeter:
- Provides firm edge support and facilitates safe patient transfers
- Heel slope:
- Redistributes pressure away from vulnerable heels
- Self-adjustment can be open cell or closed cell to meet individual needs
- Self-Adjusting air cells recognize body weight and pressure and adjust to reduce interface pressure and improve patient comfort
- Eight non-circular cylinders prevent "rolling" or "gapping"
- Removable 4-way stretch PU cover is fluid resistant, low shear and vapor permeable helping protect the skin from friction and moisture
- Arrives patient ready, easy to deliver, set up and transport
- Foam and cover are antimicrobial, antifungal
- Latex-free
- Mattress Cover Material:
- Fluid-Resistant Stretch
- Weight capacity:
- 35"W: 500 lbs
- 42"W: 700 lbs
- Control Unit Airflow:
- 4 LPM
- Control Unit Cycle Time:
- 5 Minutes
- Control Unit Type:
- Compressor
- Click here for Owners Manual
Indications of Drive PoweredConvertible Mattress:
- Provides alternating pressure therapy
- Indicated for the prevention and treatment of any and all stage pressure ulcers when used in conjunction with a comprehensive pressure ulcer management plan
- Balanced Aire Self Adjusting Convertible support surface consists of eight air cylinders that run laterally underneath the body and are contained in a foam cavity
- On top of the air cells is a high-density foam coupled with a 2.5" thick visco-elastic foam layer zoned for pressure redistribution
- Heel section is sloped to further redistribute pressure for the sensitive heel areas
- Self-adjusting air cylinders and the foam top surface aid in pressure redistribution and in maintaining low interface pressures throughout the surface
- UserManual
More About Drive Powered Convertible Mattress
Risk and Precautions:
- Transfer:
- Standard precautions should be taken during patient transfer.
- Side Rails and Restraints:
- Use or non-use of restraints, including side rails, can be critical to patient safety.
- Serious injury or death can result from the use (potential entrapment) or non-use (potential patient falls) of side rails or other restraints.
- Monitor patients frequently to guard against patient entrapment and/or falls.
- Shock Hazard - DANGER!:
- When used as a powered system, do not remove control unit case cover.
-Â Risk for electrical shock may occur if the control unit is disassembled. Refer to qualified service personnel.
- Fluids:
- When used as a powered system, avoid spilling fluids on the control unit.
- Fluids remaining on controls can cause corrosion, which may cause components to fail or operate erratically, possibly producing potential hazards for patient and staff.
- If spills do occur, unplug the unit immediately and clean fluid from control unit wearing rubber gloves while it is unplugged to avoid any possibility of shock.
- Once the fluid is removed, check the operation of components in the area of the spill.
- Patient Migration:
- Specialty surfaces have different shear and support characteristics than conventional surfaces and may increase the risk of patient movement, sinking and/or migration into hazardous positions of entrapment and/or inadvertent bed exit.
- Monitor patients frequently to guard against patient entrapment and/or falls.
- No Smoking in Bed:
- Smoking in bed can be dangerous.
- To avoid the risk of fire, smoking in bed should never be allowed.
- Disposal:
- At the end of useful life, dispose of waste according to local requirements.
Care and Cleaning:
- Washing and Disinfection
- General Guidance:
- Because of the variety of laundry equipment, chemicals, and conditions in use, you should pre-test cleaning of the cover with your agent of choice to ensure compatibility.
- Routine Care:
- Surface wipe with neutral detergent and lukewarm water.
- Rinse thoroughly with water and dry thoroughly.
- Machine Washing/Drying:
- Wash at no higher than 120° F with a neutral detergent.
- Tumble dry at low heat setting.
- Do not use bleach and make sure cover is thoroughly dry before placing back on the mattress core.
- Disinfection:
- Surface wipe the cover with quaternary solution or 1:10 bleach/water mixture according to recommended protocols.
- Avoid over saturation and ensure the surface does not stay wet longer than the chemical manufacturers guidelines for proper disinfecting.
- Wipe up excess disinfectant after the recommended kill time has elapsed.
- Thoroughly rinse the surface of the mattress with clean water using a clean cloth.
- Allow the surface to completely air dry prior to use.
- Phenolics may be used for the vinyl bottom of the cover only
- Storage:
- When not in use, mattress should be stored flat in a controlled climate room
Cleaning Control Unit and Tubes:
- Ensure control unit is unplugged.
- Wipe the surface of the control unit and tubes with coarse cloth using an approved disinfectant germicide mix and following the manufacturers instructions for use.
- Do not flood any part of the control unit with cleaning solution.
- Avoid spilling solutions on control unit controls.
- If spills do occur, clean fluid from control unit wearing rubber gloves or while the unit is unplugged to avoid any possibility of shock.
- Once the fluid is removed, check the operation of components in the area of the spill.
- Fluids remaining on controls can cause corrosion, which may cause components to fail or operate erratically, possibly producing potential hazards for patient and staff.
- Wipe off excess solution.
- Disinfect control unit and tubes with a chlorine solution (mixed accordingly). Using a clean cloth, wring out the excess solution until the cloth is damp. Wipe control unit surface and tubes with a damp cloth.
- Allow to air dry
Contraindications:
- Patient conditions for which the application of pressure redistributing therapy is contraindicated are as follows:
- Unstable spinal cord injuries
 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Warranty
5 Year Limited Warranty on Mattress. 1 Year Warranty on Control Unit.