Save 25% On Your First Autoship Order

Day
:
:
Online since 2002 |   +1 866-316-0162

View product option
Chattanooga Intelect RPW 2 Shockwave Therapy System Chattanooga Intelect RPW 2 Shockwave Therapy System Chattanooga Intelect RPW 2 Shockwave Therapy System

Chattanooga Intelect RPW 2 Shockwave Therapy System

Authorized Retailer BadgeAuthorized Retailer
Product Option

120 V Shockwave Therapy

SKU 2176KIT
$17,305.60 Each
Request quote

Chattanooga Intelect RPW 2 Shockwave Therapy System brings the next generation of shockwave therapy to the treatment room using radial pressure wave technology. It is designed to activate connective tissue from the surface level to difficult-to-reach pathologies

$19,228.49

Total: $17,305.60

Earn $519.17 in HPFY rewards
For Assistance 877-278-6039

Features of Intelect RPW 2 Shockwave Therapy System

  • The New Falcon handpiece provides a greater pressure range from 0.3 to 5 bar, making it more comfortable for the patient.
  • High resolution 7” capacitive graphic color touch screen for greater customer experience.
  • The V-ACTOR HF handpiece allows vibration frequency up to 50Hz for Vibration therapy and muscle relaxation.
  • Has 17 different transmitters available for tendinopathies, trigger points, spine and fascia treatments.
  • The Slim design 41x42x110cm (LxWxH) is an easy fit for every treatment room.
  • Unique automatic energy ramp-up designed to provide better patient comfort.
  • The protocols library feature allows you to have treatment pictures, anatomical and pathological library, and treatment guidelines at finger tips.

Indications:

  • Achilles Tendinopathy
  • Disorders of Tendons Insertions
  • Pain and Inflammation in Orthopaedic Conditions
  • Plantar Fasciitis
  • Pulse Vibration Massage

How to Use Intelect Shockwave Therapy System

  • Let your patient rest in a relaxing position during the treatment session.
  • Provide them a rolled-up towel under their limb for comfort if needed during an elevated treatment and make them feel comfortable.
  • Localise the painful points you plan to treat and it might be a good idea to mark up the points with a felt tip pen.
  • Select the most appropriate transmitters based on treatment goal and targeted tissue.
  • Apply ultrasound water-based gel on the skin overlying the treatment area.
  • Always start with a lower level of intensity and perform a post-treatment test to see for better function and decreased pain.

Frequently Bought Together

More instructions:

  • Unpacking the Device:
    • Position the transport packaging so that the arrows are pointing upward and safely remove the safety bands from the packaging.
    • Using at least 2 people, lift the device from the lower packaging element and inspect the device for any damages before proceeding.
    • Verify that the packaging contains all the required components
    • Lift the equipment carefully from the box and place it on a clean and stable surface.
    • A pouch is provided with the device. That can be attached to the side of the device handle, useful for accessories storage.
    • The Gel Holder cup can be attached to any side of the device.
    • Lastly, attach the cable holder that is used to hang the handpiece cables.
  • Falcon Handpiece Set Up
    • Unscrew the shaft from the handpiece and pull it out of the handpiece handle using the supplied open-end spanner.
    • Insert the new projectile into the fitted guiding tube.
    • Screw the shaft into the handpiece until finger-tight and using one hand, press the handpiece firmly onto the table and tighten the shaft.
    • Screw the transmitter screw cap with the required transmitter firmly back onto the shaft and make sure they are screwed firmly in place.
    • Lastly, connect the Falcon handpiece to the right connector on the device.

Warning and Precaution

  • This device should be used only by a physician or licensed practitioner.
  • Contaminated transmitters and gel can lead to infection. Disinfect the handpiece after each treatment.
  • DO NOT operate this device in an environment where other devices are being used that intentionally radiate electromagnetic energy in an unshielded manner.
  • DO NOT apply more than 300 shocks to the same spot during treatment.
  • This equipment is not designed to prevent the ingress of water or liquids.
  • DO NOT disassemble, modify, or remodel the device or accessories. This may cause device damage, malfunction, electrical shock, or personal injury.
  • Operating the device at pressures higher than 3 bar without an impact surface can result in damage to the handset.

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close