The Bacti-Guard silver alloy coating and Bard hydrogel combine to make the Bard Lubri-Sil Two-Way I.C. Infection Control Foley Catheter With 5cc Balloon Capacity a technologically advanced device. The layer is intended to limit the adhesion of bacteria that are typically associated with catheter-related urinary tract infections and minimize biofilm formation and improve patient comfort (CAUTIs).

Why choose Bard Lubri-Sil I.C. Two-Way Foley Catheter?

  • Antimicrobial 100% silicone.
  • 5cc Balloon.
  • Standard tip.
  • Reduces biofilm formation.
  • Sterile.
  • Latex-Free.

Autoship

$27.75 $46.25

25% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $1.85 in HPFY rewards

One-time purchase

$37.00 $46.25

Earn $1.85 in HPFY rewards

Bard Two-Way Infection Control Foley Catheter Features

  • Reduces bacterial adherence.
  • Bard hydrogel coating reduces friction and irritation.
  • The catheter surface resists encrustation.
  • Available in a full line of Foley catheters and Foley catheter trays.
  • Bard Infection Control Foley Catheter contains BACTI-GUARD silver alloy coating. BACTI-GUARD is a registered trademark of Bactiguard AB.
  • For single use only.

What to buy with Bard Lubri-Sil I.C. Catheter


How to use Bard Two-Way Infection Control Foley Catheter?

Bard Lubri-Sil Infection Control Foley Catheter Inflation:

  • Ensure that the Bard Foley catheter balloon is positioned well within the patient's bladder. Slowly, with a gentle, constant force, inflate the Bard. Foley catheter balloon with the volume prescribed on the package.
  • Note that the 5cc balloon must be raised with between 9cc or 10cc of sterile water.
  • Improperly inflated Bard Foley catheter balloons may cause drainage and deflation difficulties.
  • Using fluid other than clean water may cause the balloon not to empty properly, especially after long dwell times.

Bard Lubri-Sil Infection Control Foley Catheter Deflation:

  • Select a Luer slip syringe.
  • Slide the syringe's plunger up and down the barrel of the needle several times to loosen it up.
  • Compress the plunger and then pull back the plunger slightly so that it does not adhere to the front of the syringe barrel.
  • Gently insert the syringe into the catheter valve.
  • Do not use more force than is required to make the syringe stick in the valve.
  • Allow the pressure within the balloon to force the plunger back and fill the syringe with water.
  • If you notice slow or no deflation, re-seat the syringe gently. Once again, allow the balloon to deflate slowly on its own.
  • If the balloon does not deflate, reposition the patient.
  • Ensure that the catheter is not in traction, the proximal end is not compressed within the bladder's neck.
  • Ensure that urine flows freely.
  • Attempt to deflate the balloon by using the pressure in the balloon to force water into the syringe as described above.
  • If the balloon stills fail to deflate, apply very gentle slow aspiration. Aspiration that is too rapid or too forceful may cause the inflation lumen within the Foley catheter to collapse.
  • If permitted by hospital protocol, the valve arm may be severed.
  • If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol.

Warnings:

  • After use, this product may be a potential biohazard. Handle and dispose of the following accepted medical practice and applicable local, state, and federal laws and regulations.
  • On catheters, do not use ointments or lubricants having a petrolatum base. They will damage latex and may cause the balloon to burst.
  • Store catheters at room temperature away from direct exposure to light, preferably in the original box.
  • Visually inspect the product for any imperfections or surface deterioration before use. Use Luer tip syringe to inflate with stated ml of sterile water OR for pre-filled products, remove the clip and squeeze the reservoir to inflate with stated ml of pure water.

Bard Foley Catheter With 5cc Balloon Capacity Specifications

Particular Specification
Catheter Tip Standard Tip
Catheter Material Silicone
Gender Unisex
Catheter Coating Hydrogel Coated
Catheter Style Coated Catheters
Catheter French Size 12FR, 14FR, 16FR, 18FR, 20FR, 22FR, 24FR
Ballon Size (CC) 5cc

 

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close