Save 25% On Your First Autoship Order

Day
:
:
Online since 2002 |   +1 866-316-0162

View product option

Atos Medical Provox FreeHands FlexiVoice

Authorized Retailer BadgeAuthorized Retailer
Product Option

Light

SKU 8161
$329.89 Each

Medium

SKU 8162
$329.89 Each

Strong

SKU 8163
$329.89 Each
Request quote

Atos Medical Provox FreeHands FlexiVoice offers both the freedom to speak hands-free and with finger occlusion when wanted. For hands-free speech, you can choose between 3 different strengths: light, medium, and strong. The choice depends on how much airflow and pressure you need for speaking and breathing. It reduces mucus production and coughing.

Autoship

$309.89 $457.19

25% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $16.49 in HPFY rewards

One-time purchase

$329.89 $457.19

Earn $16.49 in HPFY rewards

Atos Medical Provox FreeHands FlexiVoice Features

  • Speak hands-free speech or with finger occlusion when wanted
  • Use different devices for different situations
  • Lock for physical activity
  • Fast set up
  • Reduces mucus production and coughing
  • Lightweight and discreet, ensures comfortable long-term use
  • Ergonomic design minimizes discomfort and irritation
  • Durable body ensures longevity and provides reliable performance over time

Atos Medical Provox Hands Free includes

  • 1 Speaking Valve (of chosen strength)
  • 1 Arch
  • 1 Removal Aid


Click here for user manual

What to buy with Provox FreeHands FlexiVoice


Instructions For Use

Operating Instructions

  • Do not use the speaking valve during sleep.
  • The opening of the speaking valve may be covered or the speaking valve may unintentionally be turned to speaking mode resulting in restricted breathing.
  • During sleep, use a Provox XtraHME cassette or a Provox HME Cap assembled with a HME cassette.

How to Assemble?

  • Place the HME cassette on a flat surface with the plastic grid down and the open foam surface up.
  • Place the speaking valve on top of the HME cassette and push it straight down until it clicks in place.
  • Check that the speaking valve is firmly attached to the HME cassette.
  • Caution: Use of non-Provox accessories may cause product malfunction and harm to the user.

Insertion and Usage

  • Insert the Provox FreeHands FlexiVoice into the connector of the Provox HME attachment device.
  • Keep your breath normal.
  • Switch the device between the modes by rotating the top of the speaking valve until it stops in each position.
  • Caution: Rotate only the top of the speaking valve when changing modes, not the entire device.

Cleaning Instructions

In order to keep the speaking valve in a good working condition and to avoid build-up of microorganisms, it should be cleaned and disinfected daily.

  • Remove the HME cassette from the speaking valve.
  • Rinse the speaking valve carefully on both sides under lukewarm (20-40 °C) drinking water while rotating the lid back and forth for 2 minutes.
  • Mix 2 drops of dish soap in 250ml warm (35-45 °C) drinking water. Do not use boiling water since this may damage the speaking valve.
  • Put the speaking valve in speaking mode and place the speaking valve in the mixture for 15 minutes.
  • Rinse the speaking valve on both sides in warm (35-45 °C) drinking water for 15 seconds.
  • In order to reach all parts of the speaking valve, be sure that it is switched between speaking and locked mode a couple of times during rinsing.
  • Inspect the device regarding mucus and debris residues. Repeat the steps above if necessary.
  • After cleaning, place the speaking valve in speaking mode on clean gauze and leave it to air-dry for at least 2 hours.
  • Caution: Do not use the speaking valve until it is completely dry. Inhalation of disinfectant fumes can cause severe coughing and irritation of the airways.

Storage Instructions

  • When not in use, clean and disinfect the speaking valve as described above and then store it in a clean and dry container at room temperature. Protect from direct sunlight.

Disposal

  • Always follow medical practice and national requirements regarding biohazards when disposing of a used medical device.

Precautions

  • Do not administer medicated nebulizer treatment over the device since the medication can become deposited in the device.
  • Do not use humidifiers or heated humidified oxygen via a mask over the tracheostoma while using the device.
  • Do not modify the product. The speaking function and/or HME function will be lost.

Warning

  • Do not use the HME cassette without assembling it first with Provox FreeHands FlexiVoice Speaking Valve.
  • Do not use Provox FreeHands FlexiVoice with any other attachment devices than original Provox HME attachment devices.
  • Do not reuse any part of the Provox FreeHands FlexiVoice between patients. This may cause cross contamination. The device is intended for single patient use only.

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Customer Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close