Save 25% On Your First Autoship Order

Day
:
:
Online since 2002 |   +1 866-316-0162

View product option

BD Vacutainer Eclipse Blood Collection Needle

Product Option

21 Gauge x 1-1/4"

SKU 368607
$1.15 Each

Multiple Sample Luer Adapter

SKU 367290
$228.10 100/Pack
Request quote

BD Vacutainer Eclipse Blood Collection Needle offers a simple, effective way to collect blood and help reduce the possibility of accidental needlesticks with one-handed activation technique at the puncture site. The intuitive design of the advanced protection technology means there is no need to change the standard, one-handed venipuncture technique when using these needles. BD Vacutainer Eclipse Safety Blood Collection Needle is simple, easy to use.

Autoship

$0.86 $1.65

25% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $0.03 in HPFY rewards

One-time purchase

$1.15 $1.65

Earn $0.03 in HPFY rewards

BD Blood Collection Needle Features

  • Safety shield allows for one-handed activation to cover the needle completely upon withdrawal from the vein, and confirm proper activation with an audible click
  • Safety shield is already aligned with the bevel of the needle, so no extra assembly or adjustment is required by the user
  • Needles with pre-attached holders help facilities remain single-use holder compliant
  • Slim, easy-to-handle design enhances control and flexibility 
  • Blood flashback is seen clearly through translucent shield
  • Black and sterile
  • Latex-free

What to buy with BD Vacutainer Eclipse Needle


Instructions to use BD Vacutainer Needle


  1. Holding both pink safety shield and colored needle cap, twist and remove white needle cap
  2. Whil holding the pink safety shield and the colored needle cap firmly, screw holder onto needle until it fits securely and the needle is fully seated onto the holder
  3. Ready to use right out of the package, with no assembly required.
    • Gently position pink safety shield straight back toward the holder.
    • Twist and pull colored needle cap straight off. Note: The needle bevel is always in position for venipuncture when the pink safety shield is facing up. Do Not twist or rotate the pink safety shield.
  4. Perform venipuncture according to your facility’s established procedures. 
  5. Immediately after removing the needle from the vein, position thumb squarely on pink safety shield thumb pad and push pink safety shield forward to cover the needle. An audible click may be heard. Lockshield into place and inspect. DO NOT attempt to engage the safety shield by pressing against a hard surface.
  6. Discard immediately into an approved sharps disposal container. DO NOT remove the needle from the holder. Dispose of the needle and holder as one unit into the nearest sharps container. Do not reuse.

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

Vacutainer Needle Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close