Save 20% On Your First Autoship Order

Day
:
:
Online since 2002 |   866-316-0162

View product option

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber With ComfortSeal Mask

Product Option

AeroChamber Plus Z STAT With Medium Mask

SKU 78710Z
$22.99 Each

AeroChamber Plus Z STAT With Medium Mask

SKU 78710Z
$114.29 5/Pack
Request quote

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber (AVHC) is an aerosol delivery device used in conjunction with a metered dose inhaler (MDI). This aVHC is designed to make respiratory medications more effective and combines patient-centric design features that optimize respirable drug doses. AeroChamber Plus Z STAT helps improve the delivery of medications from MDI canisters. By reducing the coordination required between canister activation and inhalation helps patients use MDI correctly. It also reduces drug deposition in the mouth and throat, helping eliminate the unpleasant taste of medication or hoarseness.

The product has received highly rated reviews, with users describing it as great, simple, and effective. It seems to work exceptionally well. Overall, the feedback indicates that this product is highly recommended by its satisfied customers.

Autoship

$18.39 $38.39

20% Off* on first autoship

5% Off* on future orders

Delivery Frequency

Earn $1.15 in HPFY rewards

One-time purchase

$22.99 $38.39

Earn $1.15 in HPFY rewards

Aerochamber Plus Z Stat AVHC Features

  • Aerodynamic chamber design with AN innovative valve system that separates and filters out coarse aerosol particles
  • One-way valve holds and protects aerosol until inhalation begins
  • Delivers 22% more of the medication than the original AeroChamber
  • Universal MDI adapter allows use with most of the MDIs
  • Durable holding chamber made of unique, flexible, shatterproof plastic
  • The original valved holding chamber design has evolved into the Monaghan Aero Chamber Plus Z STAT aVHC to provide improved MDI aerosol formulations
  • Increased aerosol suspension time
  • Optimized delivery system for consistent medication availability substantially equivalent to the MDI dose
  • Easy to clean – dishwasher safe
  • Recommended by most leading MDI manufacturers

Aerochamber Parts Description (With Mask)

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber With ComfortSeal Mask

  • Exhalation Valve: Easy flow Exhalation Valve minimizes re-breathing and directs exhaled flow away from the face of the patient
  • Anti-Static Chamber: Increases aerosol suspension time to assist dose assurance of metered dose inhaler medication
  • Inhalation Valve: Low resistance Inhalation Valve makes it easier for patients with shallow or low-volume breathing patterns to inhale the medication
  • Backpiece: Universal backpiece fits all commonly prescribed Metered Dose Inhalers and Spacers 
  • ComfortSeal Mask: It is made of soft, flexible silicone and fits snuggly to the patient's face to ensure a close, comfortable fit that promotes proper drug delivery

Why choose AeroChamber Plus Z STAT?

Aerochamber With Mask Aerodynamic Valve and Baffle Design

  • A one-way valve ensures only the right-sized particles exit the chamber through inhalation
  • Low resistance and easily opens to allow the patient to inhale without difficulty
  • Allows to inhale smaller medication particles for fast and targeted delivery to the lungs
  • Prevents the patient from exhaling into the chamber, leaving any remaining medication in the chamber available for the next breath of the patient

Z STAT Aerochamber Anti-Static Chamber

  • Anti-Static Chamber of Monaghan Z Stat minimizes static charge, increasing aerosol suspension time within the chamber and making more medication available, unlike the static-prone chambers, where static-charged aerosol particles are used to attach to the chamber walls
  • A clear polymer chamber allows the medication to enter the chamber from the MDI inhaler

AeroChamber Plus Z STAT Comfort Seal Mask

  • Fits snugly and comfortably on the face
  • Makes it easier for children to take their treatments
  • Less technique dependent than a mouthpiece
  • Secure seal ensures maximized drug delivery and reduced leakage

AeroChamber Plus Exhalation Valve

  • Low resistance valve for easy and unrestrained breathing
  • Directs the exhaled medication away from the face and eyes
  • Latex-free and made of soft, flexible silicone

AeroChamber is User Friendly

  • Suitable for smaller children
  • Attractive design
  • Easy-to-read instructions
  • Simple to use and maintain
  • Dishwasher-safe components

How AeroChamber Plus Z STAT work?

AeroChamber Z Stat aVHC maximizes medication delivery to the lungs by separating small medication particles from large particles. As the patient inhales, the smaller particles float out of the one-way valve of the chamber into the respiratory tract, where they easily reach those areas of the lungs that need it the most. The Z Stat chamber holds any of the remaining small particles that are not inhaled the first time, which allows the patient to take more than one breath per puff of medicine administered. It is especially helpful for children or others who cannot achieve a high peak expiratory flow (PEF) and assures that the maximum amount of prescribed medicine reaches the lungs for optimum benefit. This model comes with a built-in ComfortSeal mask that makes it easier for children to take their treatments.

When to use Monaghan AeroChamber Plus Z STAT Chamber?

  • AeroChamber Z Stat aVHC is intended to be used by patients who are under the care or treatment of a physician or licensed healthcare professional
  • This device is to be used by these patients to administer aerosolized medication from Metered Dose Inhalers
  • The intended environments for its use include homes, hospitals, and clinics

Monaghan Plus Z STAT Anti Static Valved Holding Chamber Illustration Using With And Without aVHC:

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber With ComfortSeal Mask


What to buy with an Anti-Static Valved Holding Chamber


How to use Aerochamber Plus with Mask?

Examine the Aerochamber 1. Carefully examine the Aerochamber for damage, missing parts, or foreign objects. Any foreign objects should be removed. It should be replaced immediately if there are any damaged or missing parts. If necessary, use the inhaler (MDI) alone until a replacement is obtained. If your symptoms worsen, please seek immediate medical attention
Remove Cap of Monaghan AeroChamber 2. Before use, make sure that instructions supplied with MDI have been read. Remove cap(s)
Shake the MDI well 3. Shake the MDI well immediately before each use. Insert the MDI into the back piece of the chamber
Exhale Through the Mask 4. Apply mask to face and ensure there is an effective mask/face seal. While maintaining an effective mask/face seal, the patient should exhale through the mask
Depress MDI 5. Depress MDI at the beginning of slow, deep inhalation. Hold your breath as long as possible, up to 10 seconds before breathing out. If the patient has difficulty with slow, deep breaths, an alternative is to keep the face tight on a mask and breathe slowly 2-3 times after depressing MDI. Administer one puff at a time
Slow Down Inhalation 6. Slow down inhalation if you hear the Flow Signal Whistle sound
Wait before repeating steps 3–6 7. Follow instructions supplied with the MDI on the amount of time to wait before repeating steps 3–6 as prescribed

How to clean Monaghan Aerochamber With a Mask?


Remove the back piece 1. Remove the back piece only. Do not remove the mask or tamper with valves during cleaning
Soak both parts for 15 minutes 2. Soak both parts for 15 minutes in lukewarm water with liquid detergent. Agitate gently
Rinse in water 3. Rinse in clean water
Shake Out the Excess Water 4. Shake out excess water. Do not rub dry
Let air dry 5. Let air dry in a vertical position
Replace the back piece 6. Replace back piece when the unit is completely dry and ready for use


Cautions:

  • To ensure proper performance, it should only be cleaned according to these instructions
  • Do not leave the chamber unattended with children
  • Federal (USA) law restricts the sale of this device on or by the order of a physician

Useful Guides


Frequently Asked Questions

1. What if a patient has difficulty inhaling medication?

The Aerochamber Plus Z Stat AVHC features a highly sensitive inhalation valve designed to accommodate shallow or low-volume breathing, facilitating easier medication inhalation for patients.

2. Is the Aerochamber Plus Z Stat Chamber Anti-static?

Chambers are made with anti-static polymer, preventing static buildup. They remain static-free even when stored in plastic bags and can be used directly from the package.

3. Does the Aerochamber Plus Z Stat Chamber contain BPA?

Chambers are BPA-free, latex-free, phthalate-free, lead-free, and PVC-free.

Product Videos

Related Articles

{{x.Heading}}

{{x.ShortDescription}} ...

Share

AeroChamber+ Z STAT Reviews

Please enter your and your friends email address below.

Fields marked with * are compulsory

Your Name*
Your Email Address
Friend's Name*
Friend's Email Address
Message
The selected product information along with Reward Dollar coupon code has been successfully emailed to you and your friend.

Thank you for using www.healthproductsforyou.com

Close